AIX1000

FULLY AUTOMATED RPR SYPHILIS TESTING

The AIX1000 is the world’s first FDA Cleared, fully automated system for nontreponemal RPR Syphilis testing. Simply load your reagents and up to 192 samples, then walk away. The AIX automates the processing, analysis, reporting and archival of results for both RPR screens and titers.

GSD-Automated-RPR-Syphilis-Testing-AIX1000-90min

Cost effective & efficient.

Reduce the amount of labor overhead dedicated to RPR testing, freeing personnel to increase productivity across laboratory operations.

Improve the quality & consistency of your results.

Fully automated.

The RPR test procedure and results interpretation are fully automated. Reduce variation associated with manual testing & interpretation.

AIX1000-comparison
AIX1000-90-min-192-samples

Performs screens & titers.

Run flexible batch sizes of up to 192 samples in 90 minutes. The AIX1000 performs RPR screens and/or titers using automated protocols.

Easy access to test results.

Images of each RPR test result are stored digitally and are retrievable on demand for review anytime.

AIX1000-Upclose-software-screen
AIX1000-scan-sample

Start the run & walk away

Load sample tubes using the built-in bar code reader or intelligent racks. The AIX1000 provides full sample traceability from loading to result reporting and archiving. The AIX1000 performs the RPR test procedure for screens and titers, and automatically interprets results.

AIX1000-orbital-shaker

On-board features

The AIX1000 employs a single, dual needle probe to aliquot Gold Standard Diagnostics’ RPR reagents in up to 4, 48 well microtiter plates, and an orbital shaker to perform the automated RPR test procedure. A built-in magnetic stir plate maintains carbon reagent suspension during the run.

AIX1000-camera

Digital results

An HD camera generates images of RPR test results that are stored digitally and are retrievable on demand.

AIX1000-upclose-screen-titer

Software

Run qualitative screens & semi-quantitative titers (1:2-1:256). The AIX1000 performs the RPR test procedure for screens and titers, and automatically interprets results using a proprietary pattern recognition algorithm.

AIX1000-software-touch-interface

Intuitive, user friendly touch interface

Use the touch-screen interface to analyze, archive and retrieve results.

AIX1000-wifi-lis-compatible

Compatible with laboratory information systems

Upload and report results directly to your laboratory database without the need for manual data entry. Integrate results archiving and reporting into your laboratory information system.

Digital Results

Proprietary Gold Standard Diagnostics reagents.

non-reactive

Non-Reactive

strong-reactive

Reactive

AIX1000-rpr-kit-by-gold-standard-diagnostics

AIX1000 RPR Kit Components

  • 480 test kit
  • 10 x 48 well plates
  • 22mL Carbon Antigen
  • 350uL Reactive Control
  • 350uL Non Reactive Control

Unique Options

AIX1000-closed-lid-with-software-screen

Intelligent Racks
Automatic sample location management.

High Precision Micro-Syringe
Aspirate 1µl with less than 3% CV.

On-board Camera
Probe-mounted high-definition camera.

Built-in Barcode Reader
Streamline loading and decrease sample tracking errors.

Orbital MTP Shaker
Precise adherence to test procedure (100-400 RPM).

Small Footprint
~2 feet x 2 feet

Technical Specifications

AIX1000-by-Gold-Standard-Diagnostics-Interior

Sample Capacity
192 patient sample positions.

Reagent Positions
7 reagent positions. Built-in magnetic stir plate for carbon reagent suspension.

Test Tube Size(s)
Standard 12, 13, 16 mm diameter, up to 100 mm tall (custom racks available).

MTP Positions
4 x 48 well plate positions for screens and low titers. 3 x 48 well plate positions for high titers.

Well-Tracking
Independent well tracking and timing.

Waste & Wash Bottles
2 liter external waste bottle. 1 liter external wash bottle.

Probe/Needle
Single probe, dual needle.

Dispense Volume
Up to 300 µl.

Aspiration Volume
1 µl – 300 µl.

Orbital MTP Shaker
Amplitude: 10 mm. Speed 100-400 RPM.

LED Backlight

Power Supply
100-265V, 50-60Hz, 120W Max.

Dimensions
W: 64 cm (25.2 in), D: 57 cm (22.4 in), H: 45 cm (17.7 in), H (open): 91.5cm (36 in).

Weight
28 kg (61.7 lbs).

Software Specifications

AIX1000-upclose-software-tablet-microtiter-plate-screen

Language
Multi-language support.

Image Analysis
Proprietary digital agglutination recognition algorithm.

Results Archiving
Digitally store images for retrieval anytime.

LIS Compatible
RS232, USB, TCP/IP.

User Interface
MS Windows Graphical User Interface (Windows 7 or later).

+ OVERVIEW

FULLY AUTOMATED RPR SYPHILIS TESTING

The AIX1000 is the world’s first FDA Cleared, fully automated system for nontreponemal RPR Syphilis testing. Simply load your reagents and up to 192 samples, then walk away. The AIX automates the processing, analysis, reporting and archival of results for both RPR screens and titers.

GSD-Automated-RPR-Syphilis-Testing-AIX1000-90min

Cost effective & efficient.

Reduce the amount of labor overhead dedicated to RPR testing, freeing personnel to increase productivity across laboratory operations.

Improve the quality & consistency of your results.

Fully automated.

The RPR test procedure and results interpretation are fully automated. Reduce variation associated with manual testing & interpretation.

AIX1000-comparison
AIX1000-90-min-192-samples

Performs screens & titers.

Run flexible batch sizes of up to 192 samples in 90 minutes. The AIX1000 performs RPR screens and/or titers using automated protocols.

Easy access to test results.

Images of each RPR test result are stored digitally and are retrievable on demand for review anytime.

AIX1000-Upclose-software-screen
+ FEATURES
AIX1000-scan-sample

Start the run & walk away

Load sample tubes using the built-in bar code reader or intelligent racks. The AIX1000 provides full sample traceability from loading to result reporting and archiving. The AIX1000 performs the RPR test procedure for screens and titers, and automatically interprets results.

AIX1000-orbital-shaker

On-board features

The AIX1000 employs a single, dual needle probe to aliquot Gold Standard Diagnostics’ RPR reagents in up to 4, 48 well microtiter plates, and an orbital shaker to perform the automated RPR test procedure. A built-in magnetic stir plate maintains carbon reagent suspension during the run.

AIX1000-camera

Digital results

An HD camera generates images of RPR test results that are stored digitally and are retrievable on demand.

AIX1000-upclose-screen-titer

Software

Run qualitative screens & semi-quantitative titers (1:2-1:256). The AIX1000 performs the RPR test procedure for screens and titers, and automatically interprets results using a proprietary pattern recognition algorithm.

AIX1000-software-touch-interface

Intuitive, user friendly touch interface

Use the touch-screen interface to analyze, archive and retrieve results.

AIX1000-wifi-lis-compatible

Compatible with laboratory information systems

Upload and report results directly to your laboratory database without the need for manual data entry. Integrate results archiving and reporting into your laboratory information system.

Digital Results

Proprietary Gold Standard Diagnostics reagents.

non-reactive

Non-Reactive

strong-reactive

Reactive

+ REAGENTS
AIX1000-rpr-kit-by-gold-standard-diagnostics

AIX1000 RPR Kit Components

  • 480 test kit
  • 10 x 48 well plates
  • 22mL Carbon Antigen
  • 350uL Reactive Control
  • 350uL Non Reactive Control
+ SPECIFICATIONS

Unique Options

AIX1000-closed-lid-with-software-screen

Intelligent Racks
Automatic sample location management.

High Precision Micro-Syringe
Aspirate 1µl with less than 3% CV.

On-board Camera
Probe-mounted high-definition camera.

Built-in Barcode Reader
Streamline loading and decrease sample tracking errors.

Orbital MTP Shaker
Precise adherence to test procedure (100-400 RPM).

Small Footprint
~2 feet x 2 feet

Technical Specifications

AIX1000-by-Gold-Standard-Diagnostics-Interior

Sample Capacity
192 patient sample positions.

Reagent Positions
7 reagent positions. Built-in magnetic stir plate for carbon reagent suspension.

Test Tube Size(s)
Standard 12, 13, 16 mm diameter, up to 100 mm tall (custom racks available).

MTP Positions
4 x 48 well plate positions for screens and low titers. 3 x 48 well plate positions for high titers.

Well-Tracking
Independent well tracking and timing.

Waste & Wash Bottles
2 liter external waste bottle. 1 liter external wash bottle.

Probe/Needle
Single probe, dual needle.

Dispense Volume
Up to 300 µl.

Aspiration Volume
1 µl – 300 µl.

Orbital MTP Shaker
Amplitude: 10 mm. Speed 100-400 RPM.

LED Backlight

Power Supply
100-265V, 50-60Hz, 120W Max.

Dimensions
W: 64 cm (25.2 in), D: 57 cm (22.4 in), H: 45 cm (17.7 in), H (open): 91.5cm (36 in).

Weight
28 kg (61.7 lbs).

Software Specifications

AIX1000-upclose-software-tablet-microtiter-plate-screen

Language
Multi-language support.

Image Analysis
Proprietary digital agglutination recognition algorithm.

Results Archiving
Digitally store images for retrieval anytime.

LIS Compatible
RS232, USB, TCP/IP.

User Interface
MS Windows Graphical User Interface (Windows 7 or later).

*Patent pending

Contact Us

We're not around right now. But you can send us an email and we'll get back to you, asap.

Not readable? Change text.